Search
View Cart     Home












































CRYSTAL QUEST® 20,000 GPD Reverse Osmosis System

System Specifications

 

System Specifications

Design

Station

Gallons Per Day

20,000 @ 77 F

Dimensions ( Approx. )

63” x 39” x 54”

Weight ( Approx. )

415 lbs.

Concentrate Re-Circulate

Optional

Auto Flush

Optional

Element Size ( in. )

4040 TFC HF1

Elements ( Qty. )

10

Motor HP

5

Voltage

110 or 220 Volts AC

Hertz

60 or 50 cycle

Feed Connection

2”

Product Connection

1”

Waste Connection

1”

 

 

Operating Specifications

Minimum Feed Pressure

35 psi

Minimum NaCl - % Rejection

96%

Minimum Feed (GPM)

30

Maximum Hardness

15 Grains / Gallon

Maximum TDS

2000 ppm

Operating Pressure

150 psi

Maximum Nacl - % Rejection

98.5%

Maximum Feed (GPM)

50

Ph Range

3 – 11

Maximum Temperature

105º F

 

 
Membrane: Ten 4"x 40" TFC HF1 Membranes, For maximum rejection of impurities and high flow.
 
Membrane Housing: Ten 4" x 40" Champ Membrane Housing, Features a patented design and requires no tools for servicing.
 
Pump & Motor: One Gould's 5 HP Multistage Pump and Motor, 110 or 220 volts, 60 or 50 hertz, 3 Phase, Designed for continuous high pressures.
 
Frame: Aluminum, White Powder Coated, Corrosion resistant, and light weight.
 
Sediment Filter: One 18" FSI Bag 10 Micron Sediment Filter, Removes sediments and protects the system.
 
Sediment Filter: One 4.5" x 20" Big White 5 Micron Sediment Filter, Removes sediments and protects the system down to 5 micron.
 
Filter Housing: One 4.5" x 20" Big Grey Double O-Ring Filter Housing, Offers durability and improved sealing capabilities.
 
Pressure Gauges: Two 2.5" Gauges,0-300 PSI, Panel Mount, Glycerin Filled,  and Two 1.5" Gauges, 0-160 PSI, Top Mount Dry Gauges, For monitoring the system's operating pressure,  the filter, and carbon operating pressure.
 
Low Pressure Switch: One McCann's Low Pressure Switch, Safety device to protect the pump from running dry when there is insufficient feed water pressure.
 
Solenoid Valve: One Solenoid Valve with Manual Override, 110 or 220 Volts AC, 60 or 50 hertz Assists with the on/off functionality of the system.
 
Manual Flush Valve: One 3/4" Stainless Steel Needle Valve, Regulates the product to waste ratio (systems recovery).
 
Computer Controller: One Rotrol S-150 Computer Controller,110 or 220 volts AC, with built-in TDS monitor - pre-treat lockout, tank full contacts, magnetic motor starter, low pressure monitoring, and alarm.
 
Flow Meters: One Product (0-20 GPM) and One Waste (0-20 GPM) Flow Meters, Enables operator to accurately adjust product to waste ratio, and monitor systems performance.
 
Easy Maintenance & Operation: CRYSTAL QUEST® commercial reverse osmosis systems feature a compact design and have all of their components strategically located for easy access and inspection.
Optional Features -
 
Stainless Steel Housings: Ten 4” x 40” Puro Tech Stainless Steel Membrane Housings, 1/2” FNPT
 
High Pressure Switch: One Square D High Pressure Switch, Automatically starts when the tank pressure falls below 40 psi ,and stops when the pressure reaches 60 psi.
 
Auto Flush: This feature will flush the systems membranes with the feed water, thus extending membrane life.
 
Float Switch: One Mechanical Float Switch, For atmospheric storage tank applications.
 
Concentrate Re-Circulate w/ 0-10 GPM Flow Meter: This feature offers a higher recovery rate for the system by taking a percentage of the waste water and feeding it back into the system. 
 

Home        Policies        Contact