Search
View Cart     Home














































CRYSTAL QUEST® 7,000 GPD Reverse Osmosis System

System Specifications

 

System Specifications

Design

Vertical

Gallons Per Day

7000 @ 77 F

Dimensions ( Approx. )

30” x 38” x 47”

Weight ( Approx. )

265 lbs.

Concentrate Re-Circulate

Optional

Auto Flush

Optional

Element Size ( in. )

4040 TFC HF1

Elements ( Qty. )

4

Motor HP

1.5

Voltage

110 or 220 Volts AC

Hertz

60 or 50 cycle

Feed Connection

3/4"

Product Connection

1”

Waste Connection

1”

 

 

Operating Specifications

Minimum Feed Pressure

35 psi

Minimum NaCl - % Rejection

96%

Minimum Feed (GPM)

10

Maximum Hardness

15 Grains / Gallon

Maximum TDS

2000 ppm

Operating Pressure

150 psi

Maximum Nacl - % Rejection

98.5%

Maximum Feed (GPM)

15

Ph Range

3 – 11

Maximum Temperature

105º F

 

 
Membrane: Four 4" x 40" TFC HF1 Membranes, For maximum rejection of impurities and high flow.
 
Membrane Housing: Four 4" x 40" Champ Membrane Housing, Features a patented design and requires no tools for servicing.
 
Pump & Motor: One Goulds 1.5 HP Multistage Pump and Motor, 110 or 220 volts AC, 60 or 50 hertz, single phase, Designed for continuous high pressures.
 
Frame: Aluminum, White Powder Coated, Corrosion resistant, and light weight.
 
Sediment Filter: One 4.5" x 20" Big White 5 Micron Sediment Filter, Removes sediments and protects the system.
 
Carbon Block: One 4.5" x 20" Big White 10 Micron Carbon Block, Removes chlorine, odor, and taste from incoming feed water.
 
Sediment Filter: One 4.5" x 20" Big White 1 Micron Sediment Filter, Removes sediments and protects the system down to 1 micron.
 
Filter Housing: Three 4.5" x 20" Big Grey Double O-Ring Filter Housings, Offers durability and improved sealing capabilities.
 
Pressure Gauges: Two 2.5" Gauges, 0-300 PSI, Panel Mounted, Glycerin Filled Gauges and Two 1.5" Gauges, 0-160 PSI, Top Mounted Dry Gauges, For monitoring the system's operating pressure,  the filter and carbon operating pressure.
 
Low Pressure Switch: One McCann's Low Pressure Switch, Safety device to protect the pump from running dry when there is insufficient feed water pressure.
 
Solenoid Valve: One Solenoid Valve with Manual Override, 110 or 220 Volts AC, 60 or 50 hertz, Assists with the on/off functionality of the system.
 
Manual Flush Valve: One 1/2" Brass Needle Valve, Regulates the product to waste ratio (systems recovery).
 
Computer Controller: One Minitrol Computer Controller, 110 or 220 volts AC, with pre-treat lockout, tank full contacts, low pressure monitoring, and alarm.
 
Flow Meters: One Product (0-10 GPM) & One Waste (0-10 GPM) Flow Meters, Enables operator to accurately adjust product to waste ratio and monitor systems performance.
 
TDS Meter: One Panel Mount TDS Meter provides you with accurate readings of the feed and product water quality.
 
Easy Maintenance & Operation: CRYSTAL QUEST® commercial reverse osmosis systems feature a compact design and have all of their components strategically located for easy access and inspection.
 
Optional Features:
 
Stainless Steel Housings: Four 4” x 40” Puro Tech Stainless Steel Membrane Housings, 1/2” FNPT.
 
High Pressure Switch: One Square D High Pressure Switch, Automatically starts when the tank pressure falls below 40 psi, and stops when the pressure reaches 60 psi.
 
Auto Flush: This feature will flush the systems membranes with the feed water, thus extending membrane life.
 
Float Switch: One Mechanical Float Switch, For atmospheric storage tank applications.
 
Concentrate Re-Circulate: This feature offers a higher recovery rate for the system by taking a percentage of the waste water and feeding it back into the system.
 
 